Features
- Constant moment beam and shear beam construction
- Designed to resist overload damage
- Moisture protected
- Tension and compression loading
| Capacity | Model No. |
| 300kgf | LC5206-K300 |
| 500kgf | LC5206-K500 |
| 1tf | LC5206-T001 |
| 2tf | LC5206-T002 |
| Rated capacities | 300kgf, 500kgf, 1tf, 2tf |
| Rated output | 2mV/V±0.2% |
| Maximum safe overload | 200% of rated capacity |
| Combined error | ± 0.02% of rated output |
| Creep | ±0.1% of rated output/hour |
| Zero balance | ± 1% of rated output |
| Compensated temperature range | -10°C~+60°C/+14°F~+140°F |
| Recommended excitation voltage | 12V |
| Maximum excitation voltage | 15V |
| Input terminal resistance | Approximately 400Ω |
| Output terminal resistance | 350Ω± 3.5Ω |
| Insulation resistance | Greater than 5000MΩ at DC50V |
| Temperature effect Zero | 0.007% of rated output/°C |
| Span | 0.002% of rated output/°CTyp. |
| Cable length | 3m/118 inches (1&2t-5m/197 inches) |